$230 Micsig MDP700 High Voltage Differential probe review and comparison with the older DP10007 and the EEVblog HVP70 probe. Have Micsig fixed the CMRR issue that plauged the DP10007 design? CMRR measured and explained: GaN MOSFET Experiemnts with fibre optic high voltage probe: Reverse engineering the DP10007: 00:00 - Micsig MDP700 High Voltage Differential probe unboxing 08:50 - Basic differential probe measurement test 12:00 - Noise measurements 15:20 - CMRR measurement using FRA 21:43 - Spot frequency CMRRR measurement technique 24:51 - Measuring Unicorn farts at 100MHz 26:45 - Conclusion Forum: If you find my videos useful you may consider supporting the EEVblog on Patreon: Or with crypto: BTC: 33BsprBQNBtHuVzVwDmqWkpDjYnCouwASM ETH: 0x68114e40ff4dcdd384750500501e20acf3875f8c BCH: 35n9KBPw9T7M3NGzpS3t4nUYEf9HbRmkm4 USDC: 0x68114e40ff4dcdd384750500501e20acf3875f8c LTC: MJfK57ujxy55su4XicVGQc9wcEJf6mAoXF Web Site: Store: Other channels: EEVblog2: EEVdiscover: T-Shirts: #ElectronicsCreators #MicSig #Review Теги: eevblog,video,differential probe,micsig differential probe,high voltage,micsig dp10007,micsig dp10007 review,micsig dp10013,differential probe review,micsig,micsig mdp700,mdp700 review,hvp70,mdp700,mdp701,mdp702